VME64x Backplanes. VME / VME64x Backplanes. Extended Description. 1-1997 VITA 38 systems management for VME The system is supplied with a 8 slot backplane. On standard backplanes, boards are located on 0. 1-1997, VME extension standard. 1 has simply been enhanced with a Gigabit Ethernet Link. VME / VME64x Backplanes. HARTMANN Electronic. 16 Gigabit Ethernet Switch (Fabric) which connects the links (nodes) with one another. VXS adds additional high-speed serial data transfer up to 10 Gbps to the backplane and supports both Single and Dual Star topologies. 1. VME / VME64x Technical Data Mechanical and Climatic Parameters VME Backplanes VME64x Backplanes Operating Temperature -25°C - +85°C (active termination) -40°C - +85°C (passive termination) -40°C - +105°C (on request) Storage Temperature -40°C - +105°C -55°C - +105°C (on request) Humidity 95%, non condensing6U VME64x Backplane 12-slot without P0, compliant with ANSI/VITA 1. All WIENER VME 64x multi-layer backplanes are outfitted with 5-row 160 pin connectors for J1 and J2 as well as optionally with 133 pin hard metric connector for J0. Can be used for 96-pin VME 3U backplanes only. The 6U monolithic WIENER J1/J2 backplane fully complies with ANSI/VITA 1-1994 and IEEE-1014-1987 specifications. Our VME Backplanes are made for industrial applications in different form factors, including vertical and horizontal orientation of the backplane and cards. . Assembled and tested. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. 11098-316) 5 1: Fan; temperature-dependent speed control 6 1 Fan control module (FCM) for fan monitoring/regulating (part no. : 73972-077 • Benutzeranleitung Power-BusplatineThis Elma 21-Slot VME Chassis is used and in excellent condition. Hybrid VXS + VME64x Backplane; Conforms to ANSI/VITA41. 3-Slot 3U OpenVPX/ ComapctPCI cPCI Backplane. The extra 1U provides room for extra power bugs or busbars. 1-1997. It is designed as a 10-layer board in strip-line technology. 0. Find the right VME or VME64x system for your application, available with horizontal or vertical card cages, as subrack or desktop versions, pluggable or open frame power supplies and included cooling concept: VMEbus and VME64x systems available for 6U boards. VME64, VME64x Backplane Specification : ANSI / VITA 1. are not included with this equipment unless listed in the above stock item. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEBackplane VME-J1. Popular VME An extension to that standard called VME64x also supports geographical addressing, in a different way. Configuration: Part Number Listed on Mainframe: 32VS-0416-TV07645X-P250. 7 Increased Current. VME64x 6U 12-slot ackplane Enabling the Evolution of Technology Amphenol ackplane Assembly & System Integration Amphenol- SI have been designing, assembling and testing backplanes for more than 30 years. VME64x Backplane Card Card Card Card RT2211 3. The busses have active on. 1-1997) Systembusplatine (Backplane) • Einem AC-Netzteil mit Weitbereichseingang • Lüftern für die aktive Entwärmung der Steckkartena single board computer and other boards on the backplane. (1) VME320 is a patented backplane construction by Arizona Digital, Inc. Hartmann VXI Backplanes are at the forefront of the standard, representing the highest quality and system performance. 7 Increased Current. Die VME64x Einschubsysteme erfüllen die Schutzklasse IP 20 und dürfen deshalb nur in den entsprechenden Umgebungen eingesetzt werden. 1-1997, VME extension standard Exceeds ANSI/VITA 1-1994 and IEEE P1014 specifications 10-layer controlled impedance stripline design Active BUSGRANT, IACK daisy chain Power connections at bottom for easier cabling Superior power distribution Virtually zero crosstalk Number of Slots: 12. 7U VME64x Backplane 3-slot with P0, compliant with ANSI/VITA 1. VME64x Backplane, 6 U, 3 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEStock # 76283-1. 7 Increased Current. 7 Increased Current. Extended Description. VME64x Backplane, 6 U, 10 Slot Without P0. 12" w x 10. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. SMT Line The Elma Bustronic SMT line is over 40’ long and includes an in-line printer, a pick-and-place SMT assembly machine, re-flow. Test adapter allows measurement and testing of both 3 and 6U assemblies (CompactPCI, VME64x) Test adapter can be mounted in chassis with an overall depth of up to 220 mm. Live Insertion . VME / VME64x Backplanes. Transition Module Extender Cards Extension of VME64x RTM boards from rear of backplane. 5 References and Architecture Specifications • User Manual VME64x Backplanes Order no. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. With two coding switches on the front panel it is possible to set a constant current or load profile for +5 V and +3,3 V. e. 7 Increased Current. : 73972-103 • Short Form Manual VME64x 6U Backplanes Bestellnr. Discreet 3U high VME64 and VME64x backplanes are fully RoHS compliant and perform to ANSI/VITA 1. 6U OpenVPX Backplanes. 7 Increased Current. Gefährliche Spannung! Dieses Warnsymbol warnt vor gefährlicher Spannung. 3 Type D SOSA Single Slot Backplane. VME64x and VME64 (optional) come with an enhanced connector. VME64x System Subrack 10 U Safety 20836-220 3 R1. 1-1997, extensão VME e VITA 1. This leads to a PICMG 2. Find your backplane easily amongst the 154 products from the leading brands (Elma, AAEON, Beijer Electronics,. Backplanes. 101V64XM09-0621R. Hardware kit to mount cable assy to rear backplane shroud. 110, PXI and CompactPCI along with switched fabric configurations. 1-1997, VME extension, and VITA 1. 1, and V67. Nearly every. 2. VME64x Backplane Card Card Card Card RT2211 3. Backplanes. 7 Increased Current. Part Number: 012-983, 32220-209-0B60. This platform conforms to VITA 1. 7 Increased Current. Die VME64x Einschubsysteme erfüllen die Schutzklasse IP 20 und dürfen deshalb nur in den entsprechenden Umgebungen eingesetzt werden. Part Number: 300 02295. VME64 - VME64x (VERSAmodule Eurocard) P1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. schroff. 1, November 14, 2008 1 Safety 1. The design enables on-board termination, allowing 21-slots in a 19 -wide form factor, but with the simplicity of single-sided surface mount assembly. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 7 Increased Current. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. Hartmann VXI Backplanes are at the forefront of the standard, representing the highest quality and system performance. Includes termination passive inboard and daisy chain automatic active. Configuration: • System Power: 400W. It is designed as a 10-layer board in strip-line technology. operating at LVTTL logic levels and VME64, VME64x, or VME320(1) backplane topologies. 1 May 04, 2009. VXS In 2004, the VITA 41 architecture was created. The same style of connector is also used for switch slots, driving the centralized fabric signals. 7 Increased Current. 100")] @ ANSI/VITA 1-1994. Our experience of backplane design, manufacturing, development and electrical test technologies allows us to6U VME64x Monolithic; 6U VME Monolithic; ACCESSORIES. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEElma 7-Slot VME64x Chassis. Further information can be found in the user manual of the backplane: Order-Vector Electronics and Technology VME, VME64x, cPCI Chassis, System Enclosures, Backplanes, Subracks, Test ExtendersVME64x 6U 12-slot ackplane Enabling the Evolution of Technology Amphenol ackplane Assembly & System Integration Amphenol- SI have been designing, assembling and testing backplanes for more than 30 years. connector. 1-1997 Greater than 64MHz high speed design Shielded signal lines & Controlled Imepedence Electronic. All VME64x systems require a minimum of level 2 performance. Backplanes Our backplanes are designed to support a range of system architectures, including VME, VPX, and cPCI, to meet the diverse needs of our. *The price shown is the per piece price and does not include VAT. 7U VME64x Backplane 18 ranhuras sem P0, em conformidade com ANSI/VITA 1. Bei höheren Anforderungen an die Schutzklasse, z. 7U VME64x Backplane 6-slot w/o P0, compliant with ANSI/VITA 1. 0. 110, PXI and CompactPCI along with switched fabric configurations. Elma is the industry expert in high-performance backplanes. Bei höheren Anforderungen an die Schutzklasse, z. This configuration is based on a 16-slot VME64X backplane. : 73972-091 • User Manual Fan Control Module (FCM) Order no. 101V64XC12-1621. RsvU. 1-5 slots. Hot-Swap compatible per PICMG 2. 04. System Slot: Slot 1 Left. The busses have active on board termination and active automatic daisy-chain (CBLT compatible!). Height: 6U :Can be used for both 160-pin or 96-pin VME64x/VME 3U backplanes. Wide range of VPX backplanes designed for your ruggedized applications: compliant to VITA specifications, with or without RTM, 3 U and 6 U available. All WIENER VME 64x multi-layer backplanes are outfitted with 5-row 160 pin connectors for J1 and J2 as well as optionally with 133 pin hard metric connector for J0. There are three general types of backplanes available: Standard, 3-row connector backplanes. VME64x Backplanes From Pixus Feature Various Power Options. 7 Increased Current. VME64x Backplane, 6 U, 5 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. e. Test adapter is held firmly in place by the front and lateral guides. It was added to the 160 pin P1/J1 connector in the VME64x specification. Single-family homes make up a large proportion of the market, but Greater Victoria also has a number of high-end luxury properties. Slot Width: 4 HP. Join. 1-1997, VME extension, and VITA 1. Includes termination passive inboard and daisy chain automatic active. Show per page. • User Manual. 1-1997, VME extension, and VITA 1. RETRY* [RETRY*], together with [BERR*], can be asserted by a slave to postpone a data transfer. Subrack based, sheet metal, desktop or tower configurations. 00. FP10B4HP6UX160, VME64x Air Blocker. Backplane Height: Amphenol ABSI VME64x backplane offer 4 different height options covering 3U, 6U,7U and 9U. 3M™ MetPak™ HSHM Connector used in a VME64x backplane 2. Our experience of backplane design, manufacturing, development and electrical test technologies allows us toThe boards will be housed on a VME64X crate, in which the backplane provides rear electrical interconnections dedicated to slow control and configuration. 8" centers (i. Hot-Swap compatible per PICMG 2. pdf; OpenVPX-Backplane-SOSA. 1 Intended Application The VME64x system subrack, described in this manual, is intended as a platform for a microcomputer system based on the VME64x bus system (VITA 1. What is VMEbus The VMEbus started with the ANSI/VITA 1 specification in 1982. (For OpenVPX products, see the Pixus OpenVPX section. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME • The VMEbus backplane has 31 address lines: A01. 7 compliant VME64x 21-slot backplane with J0 connectors (VX21) = RACEway certified VME64x 21-slot backplane with J0 connectors (V021) = VME 21-slot backplane (VP21) = VITA 31. 1-1997, VME extension, and VITA 1. B. 6-10 slots passive active. 1-199x/D1. PCB connector is Harting 02-01-160-2101 male right angle. P47, 4U. Single Slot Backplane. This prototype uses the MTM bus existing in the VME64x backplane to apply the 1149. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEThe Dawn VME DEV-7713 VME64x Tabletop Development Chassis is ideal for use in office and laboratory environments. VXI Backplanes. )) Pixus has a wide range of CompactPCI, VME, VME64x, and other backplanes available off-the-shelf. 20-Slot Hybrid VME64X/ VXS Backplane. The VME64x extension, which is downwards compatible, allows higher data transfer rates and added rear I/O boards to VME. Serving physics research and other demanding high-performance test and instrumentation applications W-IE-NE-R has developed a line of backplanes and accessories in various bus architectures. 62" h x 19. 3U VPX Backplanes Dawn’s VPX backplanes are based on VPX (VITA46), VPX REDI (VITA48), OpenVPX (VITA65) and VITA 68 VPX compliance available in a wide range of profiles and topologies. 1R3 backplane. Rack Height: 6 U. Try our 3D configurators to create a design tailored for your application, download the BoM and CAD files, review pricing, and place your order online - all in minutes!Atrenne VME64x VITA 1. : 10836-060 Doc-No: 63972-161_R1. High Quality Chassis and Enclosures for VME and VME64x Applications. We also develop custom backplanes to meet your specifications, from initial concept to finished product. 6U OpenVPX and SOSA aligned Backplanes in various slot sizes and profile configurations. This platform conforms to VITA 1. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. cPCI Serial Backplanes. 7 Increased Current. VME64x Backplane, 6 U, 8 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. • User Manual VME64x Backplanes Bestellnr. A31 • There is no A00 address line on the backplane. 6 A Current loading per power bug 25A Current. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEANSI / VITA conform portfolio of VME and VME64x backplanes: Up to 21 Slots; 3 U and 6 U rack height; ANSI / VITA 1-1994 VME64; ANSI / VITA 1. The backplane trace impedance can vary between 45 Ω and 60 Ω, the stub impedance is about 60 Ω, and the connector impedance is about 67 Ω. S34-HP VME64X. IP 54/55 dürfen die. The 160 pin DIN (5 row x 32 pin) add rows "z" and "d". 8K 220 470 RT2211 Features • 8-Bit Termination Network • VME64, VME64x Compliant • Low Channel Capacitance • Laser Trimmed Resistance to ± 1% • Slim BGA Package7U VME64x Backplane 6-slot with P0, compliant with ANSI/VITA 1. OpenVPX, CompactPCI, CompactPCI Serial, VME, and VME64x are open standard backplane architectures commonly used in Eurocard systems. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 54mm (. If you love a cozy, comedic mystery, you'll love this 'whodunit' adventure. The A+C rows are bussed in all slots. 3V, +/-12V, +/-V1, +/- V2, and GND. Further information can be found in the user manual of the backplane:High performance 25 Gbaud Gen-4/5 backplanes compatible with 100 GbE (100GBASE-KR4) and PCI Express® (PCIe) Gen-4 (16 Gbaud) on OpenVPX data plane and expansion plane fabrics. Backplane Type: VME64x with EDC. • Drive Bay: None Installed. The maximum form factor expands to a 21 slot backplane. Vector uses ERNI P0 connectors. There are major new features on this product for a more faster output which. Vector uses ERNI P0 connectors. 1, and V67. VME J2 12 slot. • Backplane Slots: 9 VME64x J1/J2 Slots. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. EN. 1-1997, VME extension, and VITA 1. Hartmann Electronic’s 4 slot 19” rack mountable VME solution – The VME64x 2U system. 1-1997 VME64 Extension Standard, ANSI/VITA 1. VPX Accessories; cPCI Accessories; Ethernet Conversion Modules; Transition Module Extender Cards;. Slot Width: 4 HP. Backplane Type: VME64x with EDC. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 3 Power Backplane A Power Backplane (23098-115) is located to the right of the VME64x Backplane providing two P47 connectors to connect to 3 U / 250 W plug-in power supplies. Machen Sie sich vor101VMEJ212-0900. The VME64x backplane supports 19” rack applications. Power Interface. 0 inches required below the backplane (2. 6U VME64x Backplane 15-slot with P0, compliant with ANSI/VITA 1. 100")] @ IEEE 1014-1987; [VME] P1 and P2 are 160 pin DIN (41612, Type C. 1-1997, VME extension, and VITA 1. Live Insertion . It is designed as a 10-layer board in strip-line technology. (V021) = VME 21-slot backplane (VX21) = VME64x 21-slot backplane with J0 connectors 9 5$&(ZDFHUWL¿HGKLJKSRZHU9,7$ FRPSOLDQW90( [ VORWEDFNSODQHZLWK- FRQQHFWRUV (VP21) = VITA 31. Designed to IEEE 1101. Typical plug-in modules are 3U or 6U with a 160mm depth. Dawn VME Products. Product Type: Backplane; Number of Slots: 10; Rack Height: 6 U; Backplane Type: VME64x with EDCThe Elma Electronic VME64x backplane series is designed to fully comply with the ANSI/VITA VME extension standard. VME J2 backplane 12 slot, compliant with ANSI/VITA 1-1994. 5-2003 VME2eSST Specification, ANSI/VITA 1. operating at LVTTL logic levels and VME64, VME64x, or VME320(1) backplane topologies. 6U VME64x backplane. Architecture. The B-port I/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ V CC ± 50 mV) for increased noise immunity. This line covers standard bus systems as CAMAC, VME, CERN VME 430, VME64x, VME64xP (VIPA)VXI and VXS but also custom spec. 3 volts) and ground (GND) on P1 and 'User Defined' on P2 (next page). : 73972-083 • Benutzeranleitung Netzteil Bestellnr. 3-1997 Added 9U x 400mm IEEE 1101. Depending on local conditions, packaging and freight charges might not be included. Victoria is experiencing low. CompactPCI backplane 102CPCI306-20X0R. Primary. FPE046UX160, VME Air Blocker. downloads. 5 V – Address, address modifier and data lines are active high. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME On standard backplanes, boards are located on 0. Speeds up to 100GbE. Standard and custom backplanes include Gen3 VPX, VPX, VME, VME64, VME64x, VXI, H. VXI Backplanes. Convert Backplane SERDES interfaces (KR/KX/SGMII/USXGMII/) to 10G/1000/100 BASE-T for External Chassis interface. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEThe Bustronic VME64x backplanes come with power bugs for +5V, +3. 3c, V67. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEare “C” (6U x 340mm) and “D” (9U x 340mm) and the backplane pitch is 1. As the leader in VITA 46/65 OpenVPX backplane design and manufacturing, our cutting-edge signal. This unit ships in manufacturers box. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEVME64x Backplane, 6 U, 10 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. The Elma Bustronic VME64x backplane series is designed to fully comply with the ANSI/VITA VME extension standard. Vector offers a VMEbus and VME64x J1 only backplanes currently in 21, 16, 15, 10 and 9 slots per ANSI/VITA 1. 23207-021) 7 1: Front panel, perforated, 3 : U; display module; mains switch 8 1 AC. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEVME-VME64 6U 162 Series. WithVME and VME64x Backplanes; VMEbus J1 Backplane EDC, 3 U, 10 Slots Click image to expand into larger view; Click image to expand into larger view; Click image to expand into larger view; VMEbus J1 Backplane EDC, 3 U, 10 Slots In accordance with ANSI/VITA 1-1994 VME64 standard; 3 U with J1 plane. 1-1997, VME extension, and VITA 1. VME64x Backplane. ANSI/VITA 1. Backplane connector is Harting 02-02-160-2201 female type. The various headers are basically the same, except the 12-pin friction lock for +/- V1 and V2 has only 8 pins (one less pin per type). 3-1997 (S2021) VME64x 9U x 400mm Format. J2 Monolithic) conforms to: VITA 1. The VME64, VME64x represents an extension of the VME family. The VME64x system subracks are designed for protection class IP 20 and canBACKPLANE (V721) = RACEway certified high power VITA 1. VME64x Backplane, 6 U, 7 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. Hartmann Electronic’s slimmest 19” rack mountable VME solution – The VME64x 1U system. 5-2003 VMVME64x System Subrack 10 U Safety 20836-220 3 R1. The backplane is actively terminated and provides automatic daisy chain either. VME64x - Military VME64x backplane fitted with 5 row 160 pin J1/J2 and 95 pin J0 connectors. Part Number Listed on Chassis: 12V-1020-RV21V645X-P750-BC Backplane Configuration: 21 SlotBare Board: VME64X Backplane Part Number: 201VSBJ206View Rear Photo of ChassisDie VME64x Einschubsysteme erfüllen die Schutzklasse IP 20 und dürfen deshalb nur in den entsprechenden Umgebungen eingesetzt werden. 5-2003 VME2eSST Specification, ANSI/VITA 1. • User Manual VME64x Backplanes Bestellnr. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. Open School BC is British Columbia, Canadas foremost developer, publisher, and distributor of K-12 content, courses and educational resources. 1-1997VME64x Asynchronous 64-bit 1996 5-row P1 and P2 2eVME 2-edge handshake 160 ~70 Synchronous 64-bit 1999 No change 2eSST No handshake 320 ~320 An 8x improvement in achievable performance from the VME64 backplane to 2eSST is now possible without any changes to the existing legacy backplane architecture. VME64xK - Military VME64xK backplane fitted with 5 row 160 pin J1/J2 & 75 pin key-slot J0 connectors have polarizing keys so that any given board fits only in its connector-coded slot, protecting against card insertion errors (ref: VME64xK). Number of Slots: 12. 1-1997 Compliant to : ANSI / VITA 1. Hot swap (in conjunction with VME64x backplane) VME64x Connectors VME64x Side Shielding VME64x Front panel VME64x extractor handles (on request) single supply (+5 V) in field firmware upgrade capability. 3U, 6U and 9U VMEbus, VME64x and Universal testing applications test and form factor extender boards. 5-2003 VME2eSST Specification, ANSI/VITA 1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. This platform conforms to VITA 1. S34 Commerical. are “C” (6U x 340mm) and “D” (9U x 340mm) and the backplane pitch is 1. backplane VME64x 101V64XM18-0620R . Schroff VME / VME64x backplanes are specially designed to achieve excellent power distribution, best signal integrity and virtually zero cross talk, The SMD components used on Schroff VME / VME64x backplanes lead to a much lower failure rate than conventional components. The same style of connector is also used for switch slots, driving the centralized fabric signals. CompactPCI with access to the test boards from 3 sides / 3U or 6U ME and. 6U OpenVPX Backplanes. bus is based on J1-only version of the VME64x backplane, which utilizes 160-pin 5-row connectors. OpenVPX is the architecture framework that defines system level VPX interoperability for multi-vendor, multi-module, integrated system environments. 6U VME64x Backplane 11-slot without P0, compliant with ANSI/VITA 1. Part Number: 11-1011777-2119. 600W universal input power with PFC. downloads. 8” pitch versus a typical 1. 6" d P2 and P0 backplane backside connector pins required Minimum 2. S34 Commerical. Amphenol supplies an adapter interconnect system for “cocooning” of COTS VME64x daughtercards. ) on DirectIndustry, the industry specialist for your professional purchases. VME64x Backplane, 6 U, 2 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 5 Gbps Pci-Express and RapidIO are vehicled on the classical VME64x backplane 3M column-based differential pair B19 HSHM model as P0 SBC connector Customer investments preserved: VME64x, VITA31,. 1-1997 while providing a low profile, practical packaging solution for high-performance. It was added to the 160 pin P1/J1 connector in the VME64x specification. Monolithic VME64x backplanes are available with 7, 10 or 21 (full size) slots. 1-1997 VME64 Extension Standard, ANSI/VITA 1. General Backplane Specification for VME and VME64x Slot Count : 2-21 slot options Size : “True” 6U, 10. 6 mm. VME64x uses the VME parallel bus across a 160-pin DIN connector. VME64x 5-row connector backplanes with 160 pin enhanced connector. VME Cards may be produced which respond to the following Address widths or. S34 VME64X. Number of slots. Seventeen models are available offering from five to 21 slots. Up to 36,864 channels from a focal plane with 24×24 SiPM 64 pixel arrays can be handled by a 8-slot VME64X crate, in which 6 slots will be dedicated to Level 2 trigger boards, 1 slot for. VME64x backplanes must not bus or terminate this signal. This thin VME chassis comes with a 300W cPCI hot-swap power supply and horizontally oriented card slots. FPE043UX160: 3U x 160mm x 4HP: VME, 1101. Chassis – Turnkey, Fully Assembled and Tested, Convection, Conduction and Liquid Cooling. All Elma Electronic VME backplanes are designed to maximize performance, minimize noise, and to give the customer the most reliable, cost-effective product possible. 5 Gbps through Tx+RX connectors ANSI/VITA 1. RETRY* [RETRY*], together with [BERR*], can be asserted by a slave to postpone a data transfer. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. • User Manual. Item Description. 5-2003 VME2eSST Specification, ANSI/VITA 1. Vector offers a VMEbus and VME64x J1 only backplanes currently in 21, 16, 15, 10 and 9 slots per ANSI/VITA 1. Includes termination passive inboard and daisy chain automatic active. All VME / VME64x Backplanes 0 of 0 results All. It defines a set of features that can be added to the VME and the VME64 boards, backpanes and sub-racks. cPCI Serial Backplanes Our serial. 1-1997) geeignet. VXI Backplanes. This manual provides detailed information on the features, specifications, wiring and troubleshooting of the backplanes. Page 9: Vme64X Backplane Order-No. VXI Backplanes. J2 Monolithic) with P0 connectors conforms to: VITA 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME7U VME64x Backplane 6-slot w/o P0, compliant with ANSI/VITA 1. Elma is a leading contributor to the DoD hardware convergence and tri-service commonality initiatives, providing CMOSS / SOSA-aligned technology, backplanes and modules pursuant to the stated goals of those initiatives. The retry cycle prevents deadlock (deadlystandard VME64x cards and backplanes, but it does not mate to other types of VME commercial connectors. 101V64XC05-0621R. The busses have active on board termination and active automatic daisy-chain (CBLT compatible!). 3V 1. VXS uses a straightforwardxHot swap (in conjunction with VME64x backplane) xVME64x Connectors xVME64x Side Shielding xVME64x Front panel xVME64x extractor handles (on request) xsingle supply (+5 V) xin field firmware upgrade capability. Read More7U VME64x Backplane 7-slot w/o P0, compliant with ANSI/VITA 1. Blaze VXS (Bs series) - VXS Backplanes. VXI Backplanes. The Elma Electronic 6U VME64x Backplane 5-slot with P0, compliant with ANSI/VITA 1. Includes termination passive inboard and daisy chain automatic active. 5-2003 VME2eSST Specification, ANSI/VITA 1. 7U Vme64x BACKPLANES - Elma Electronic. 54mm (. 056-301 6U/149 W air cooled load board for VME64x backplaneVME64x backplane. This Comtel Electronics VME64x 7-Slot Backplane is new from surplus stock. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEthe backplane. Unobstructed. The extra 1U provides room for extra power bugs or busbars. Serving physics research and other demanding high-performance test and instrumentation applications W-IE-NE-R has developed a line of backplanes and accessories in various bus architectures. Each of these styles of backplanes are available in 3U and 6U form factors. The original specification was sponsored by VITA and eventually standardized as IEEE 1014. 1-1997, VME extension standard. Hartmann VXS Backplanes offer the highest quality and performance in the standard at a cost that won’t bankrupt your project. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 3U backplane VME64x 1U/84HP 2 Slots. 1 test vectors to a system composed of nineteen boards, called here units under test (UUTs). The Elma / Bustronic VME64x Backplane is designed to fully comply with the ANSI/VITA VME extension standard. 1-1997 VME64x; ANSI / VITA 1. 1-1997 and 1. WIENER J1 VME backplanes are available with 5, 7, 9, 10, 15 or 21 (full size) slots. 1-5 slots. 6U VME64x Backplane 8-slot with P0, compliant with ANSI/VITA 1. The term ‘VME’ stands for VERSAmodule Eurocard and was first coined in 1980 by the group of manufacturers who defined it. 3 RF/Optical modules. There are three general types of backplanes available: Standard, 3-row connector backplanes.